Resumen
This document describes the following:
— a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements;
NOTE 1 For the background interlaboratory study used to verify the test methodology, see Annex D.
— a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics;
— a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≥ 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L;
NOTE 2 It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.
— a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A.
This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.
This document applies to three test conditions:
— test condition 1, with a base upstream gravimetric level of 3 mg/L;
— test condition 2, with a base upstream gravimetric level of 10 mg/L;
— test condition 3, with a base upstream gravimetric level of 15 mg/L.
Informaciones generales
-
Estado: PublicadoFecha de publicación: 2022-01Etapa: Norma Internacional publicada [60.60]
-
Edición: 3Número de páginas: 43
-
Comité Técnico :ISO/TC 131/SC 6ICS :23.100.60
- RSS actualizaciones
Ciclo de vida
-
Anteriormente
RetiradaISO 16889:2008
RetiradaISO 16889:2008/Amd 1:2018
-
Ahora