Abstract
The principle of the method specified is dissolving the sample in dilute nitric acid and determining the silver content of the resulting solution by titration with standard potassium bromide solution, using a potentiometric indication of the equivalence point. The alloys, preferably within the range of fineness stated in ISO 9202, may contain copper, zinc, cadmium and palladium. Apart from palladium, which must be precipitated before commencing titration, these elements do not interfere with this method of determination.
General information
-
Status: WithdrawnPublication date: 1993-05Stage: Withdrawal of International Standard [95.99]
-
Edition: 1Number of pages: 3
-
Technical Committee :ISO/TC 174ICS :39.060
- RSS updates
Life cycle
-
Now
-
00
Preliminary
-
10
Proposal
-
20
Preparatory
-
30
Committee
-
40
Enquiry
-
50
Approval
-
60
Publication
-
90
Review
-
95
Withdrawal
Corrigenda
Correct the current edition; free; not included in the text of the existing standard.WithdrawnISO 11427:1993/Cor 1:1994
-
00
-
Revised by
WithdrawnISO 11427:2014